Project

General

Profile

Bug #351

L17更新2.2.3前---CCTV测试

Added by lq Du about 5 years ago. Updated over 4 years ago.

Status:
Closed
Priority:
Normal
Assignee:
Target version:
Start date:
11/28/2019
Due date:
% Done:

100%

Estimated time:
Defect version:

Description

L17#现场版本和V2.2.3版本对比CTV下发指令不同
!!!更新2.2.3 em_daq闪退,故替换现场endaq.exe进行测试!!!
[1] 总调的监视器字节不一致 旧 【0f】 新【12】 [2] PTZ控制 旧 发三条命令 ;【调图+鼠标点+鼠标弹】 新 【鼠标点+鼠标弹】 ;[3] cctv_车站插件默认是2X3 窗号为 01-06 且56窗显示不全 ;


Files

C3cctvUi_现场.ini (592 Bytes) C3cctvUi_现场.ini lq Du, 11/29/2019 10:34 AM
C3cctvUi_2.23_行调3&总调.ini (1.49 KB) C3cctvUi_2.23_行调3&总调.ini lq Du, 11/29/2019 10:34 AM
L17#cctv测试_v_2.23.txt (4.3 KB) L17#cctv测试_v_2.23.txt lq Du, 11/29/2019 10:34 AM
L17#cctv测试_v_site.txt (4.26 KB) L17#cctv测试_v_site.txt lq Du, 11/29/2019 10:34 AM
测试总结.txt (370 Bytes) 测试总结.txt lq Du, 11/29/2019 10:34 AM

History

#1

Updated by xiangyang li about 5 years ago

  • Assignee set to zhixue wei
  • Target version set to 2.2.3 sp1
#2

Updated by zhixue wei about 5 years ago

  • Status changed from New to Resolved
  • % Done changed from 0 to 100

问题1:总调的监视器字节不一致是因为C3cctvUi_现场.ini文件dispatchCount = 4,而调用的是第5个监视器。解决办法:将ini文件里的dispatchCount配为5,应该有多少个监视器就配多少。
问题2:原因是C3cctvUi_2.23_行调3&总调.ini文件DigAnaCCTVtype = 17,导致17号线做PTZ控制前未做一次切换摄像头的动作。
解决办法:将C3cctvUi里做切换摄像头动作的函数关于对DigAnaCCTVtype的判断注释。
问题3:3.0版本代码已修改此问题

#3

Updated by xiangyang li over 4 years ago

  • Status changed from Resolved to Closed

Also available in: Atom PDF